1. AC output

Voltage scope: 0 - 600V

Range: 25V, 50V, 110V, 200V, 400V, 600V

Current scope: 0 ~ 24A

Rated current range: 0.1A、0.5A、1A、5A、10A、20A

Voltage current regulation range: 0~120%

Voltage current regulation fineness: 5×10-5

Voltage current error ≤0.03%(Rd)±0.02%(full range),0.05 level

Voltage current output power: every rated range full scale 100% ≥ 20W

Output frequency:

Range: 45 Hz ~ 65 Hz

Resolution: 0.001 Hz

Accuracy: 0.01 Hz

Output phase:

Range: 0 ~ 359.99°

fineness: 0.010

Accuracy: 0.01°

Output Harmonic:

Orders: 2~51 orders

Amplitude: 0~20%

Each order phase position fineness: 0.010·N(N is harmonic order number)

Output Power

Output power scope: ranged current range and rated voltage range can be mixed arbitrarily

Accuracy: 0.1, 0.05 level within rated range ( reactive power accuracy will be one level lower)

Output waveform distortation: AC voltage current ≤0.3%

Energy Meter measurement:

Integrated error: 0.1、0.05% FS (impulse output ≤90kHz, three phase rated vaule=60kHz)

2. DC output

DC voltage range: 75mV,1V,3V,7.5V,15V,30V, output capacitance: 100mA

                75V、150V、300V、600V、1000V, output capacitance: 40mA

DC current range: 30uA、300uA、3mA、30mA、maximum output capacitance: 9VA

    300mA、0.5、1、2.5、5A 、10A 、20A maximum output capacitance 10VA

DC voltage, current regulation range: 0~120% FS, fineness: 5×10-5

Rated Voltage range accuracy: error ≤0.06%(Rd)±0.04%(full range), 0.1 level
                            error≤0.03%(Rd)±0.02%(full range), 0.05 level

Rated current range accuracy: error ≤0.06%(Rd)±0.04%(full range), 0.1 level
                            error≤0.03%(Rd)±0.02%(full range), 0.05 level

DC 75mV output (load≥200Ω) accuracy

error≤0.12%(Rd)±0.08%(full range), 0.2 level

error≤0.06%(Rd)±0.04%(full range), 0.1 level

Others:

Working power supply: Single phase 220V±10%, 50Hz±5%

Working environment: temperature 20℃±10℃ relative humidity≤85%RH

Size and Weight: 460×480×200mm, 18kg