+86-27-65526006

+86-27-65526007

Home > Products > ZX3030H DC/AC Three Phase Standard Source

ZX3030H DC/AC Three Phase Standard Source

It is composed of program control three phase standard source, DC standard source, Three phase sampling type multifunctional standard meter, and computer with standard table and management software installed.

Features
Technical indicators

1. AC output voltage current

Voltage range: 10、20、50、100、200、400、600V

Current range: 0.1、0.25、0.5、1、2.5、5、10、25、50、100

Regulation range: 0~120%( but 800V、100A: 105% )

Regulation fineness: 0.005%

Output voltage current power stability:  ≤0.01%/60s

maximum output capacity of voltage per phase: 50VA

maximum output capacity of current per phase: 100VA

sine wave output distortion: ≤0.3%

2. Output phase

Phase drift of current to the same voltage: 0.000~359.990

Regulation fineness: 0.010

3. output frequency

Regulation range: 45~65Hz 

Setting value accuracy : 5×10-5
4. Distortion wave output

Harmonic order: 2-31

Harmonic numbers contented at the same time: 0~30

Harmonic amplitude: total harmonic peak-peak value, should not be more than 50% of fundamental wave rated value (voltage current range, expressed in peak-peak value), besides, distortion wave peak-peak value including fundamental wave should not be more than 125% of fundamental wave rated value.

Phase drift of each order harmonic to fundamental wave( fundamental wave positive zero crossing as reference): 0~360°

5. Three phase angle symmetry

Three phase four line: between the phase voltage: 1200±0.20

Three phase three line: UAB is UCB lagging behind 600±0.20

6. DC output voltage ( auxiliary range not included)

Range: mV:100、300
   V:1、3、10、30、100、300、600、1000

7. DC output current ( auxiliary range not included)

uA:10、30、100、300
mA:1、3、10、30、100、300
A:1、3、10、30 

8. DC output capacity: maximum 30W

9. DC output regulation range and fineness

Range: 0~120% ( but voltage 1000V, current 30A: 105%)

Fineness: 0.002%

10. DC output accuracy: 0.05%

11. stability of DC full range output: ≤±0.01% RG/1min

12. error caused by ripple and noise voltage: ≤±0.01% RG

13. error caused by loading change of no-load to full-load: ≤±0.01% RG

14. device accuracy class: 0.05

1) allowed measuring error of voltage/current/active power: (5V≤U≤1000V,0.1A≤I≤100A) 0.05%

2) allowed measuring error of active power energy: (25V≤U≤800V, 0.1A≤I≤100A) 0.05%

3) allowed measuring error of reactive power/energy: 0.1%

4) phase measuring error: ±0.050

5) power factor measuring error: ±0.0002

15. Power supply: Single phase 220V±10%, 50HZ±5%

16. working environment: temperature 200℃±100℃, relative humidity ≤85%RH

17. dimension and weight: 1800×800×750mm3, 135kg

Service commitment